After recharging carbon dioxide fire extinguishers and stored pressure type fire extinguishers, they are checked on impermeability.Īll fire extinguishers shall be recharged immediately after their use, or in case the amount of gaseous fire extinguishing agent or displacing gas (in 1 year) exceeds the limit (GOST 51057 and GOST R 51017), but not less than terms specified in Table 1. Powder fire extinguishers, that are mounted in vehicles or those that have undergone the adverse climatic and (or) mechanical factors, must be recharged at least once a year. Fire extinguishers shall be recharged after their use for the intended purpose or after examination results. Once in five years a complete replacement of the extinguishing agent is conducted as well as the hydraulic pressure test of fire extinguishers. During this process, pressure in the housing is determined, a fire extinguisher is weighed, the signs of deformation and damages are checked and range of the following works to be executed is determined.įire extinguishers recharge is a stage of the process of fire extinguisher maintenance which aim is to replace the fire extinguishing agent. Inspection and testing of fire extinguishing agent is a fire extinguisher inspection for compliance with its requirements. Weighing of a fire extinguisher (to determine the amount of carbon dioxide in it) Inspection of fire extinguishing agent and carbon dioxide fire extinguishers includes the following operations: Sticking on a label that fire extinguisher maintenance has been conducted. Inspection of fire extinguishing agent and dry powder fire extinguishers includes the following operations:Ĭhecking the marketable condition of a fire extinguisher If at least one of the parameters does not meet the requirements of the normative and technical documentation, all fire extinguishers of this brand shall be recharged. Then fire extinguishing powder is inspected according to such basic operational parameters as overall appearance, presence of lumps or foreign objects, possibility of splitting small lumps to the pulverized state as they fall from 20 cm height, moisture and dispersion. At an annual technical inspection a powder fire extinguisher (not less than 3% of the total number of fire extinguishers of the same brand, but not less than 1 item) is disassembled. Inspection of fire extinguishing agent is a stage of the process of fire extinguisher maintenance which aim is to determine the technical condition of fire extinguisher, to find a malfunction and to decide whether it needs repairing, inspecting, recharging or writing-off. The maintenance of fire extinguishers includes the following steps: They also are to be maintained after the end of the warranty period, after its usage as well as with the onset of the next period of maintenance. Fire extinguishers shall be maintained in case of visible damages, the lack of labels, seals or blocking devices, presence of mechanical damages and corrosion, the absence of operating pressure. We`ve developed a flexible discount system not only on services but also on the whole range of fire-fighting equipment.įire extinguisher maintenance is a complex of measures aimed to prevent malfunctions and ensure its efficiency in a standby mode, while transportation and storage. Our specialists can advise on any question concerning fire safety. You will find a reliable and trustworthy supplier of firefighting services and equipment. We are used to build long-term relationship with our clients. When working with the customer, our primary concern is the solution of your problems in the field of fire safety. Our specialists will advise you on maintenance, recharge and technological process concerning the primary fire extinguishing equipment. We have selected a team of highly skilled professionals with extensive experience and specially trained to carry out fire extinguishers maintenance skillfully and competently. We have modern equipment to perform high-level works such as inspection of fire extinguishing agent test, repair and recharge of fire extinguishers. For this purpose, there is a station for fire extinguisher maintenance. Therefore, to ensure the reliability and availability of fire extinguishers, we conduct their maintenance, discover potential problems and eliminate them. Fire extinguishers are the first means of combating ignition and extinguishing fires. Maintenance of primary fire extinguishing means is one of the main duties of those people responsible for fire safety.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |